SQL 2012 - Low PLE on one node in failover cluster

$
0
0

Hoping someone else has experienced this behavior before.

We have two 2008 R2 failover cluster nodes running SQL 2012

One node has 128 GB of memory.  The one showing continuous low PLE has 156 GB.  While I realize that these need to be balanced out, I am trying to understand how/why the one with more memory would be exhibiting constant low PLE while SQL is running on that node

As soon as I fail over to the node with less memory, PLE returns to normal.

Both nodes are running identical hardware otherwise, same connectivity to storage.